loading

Zetron Instrument focuses on providing customized solutions for precision analysis and monitoring.

Oil Particle Counter

The oil particle counter is specifically designed to detect particulate contaminants in oil. Using the principle of light scattering or light blockage, when oil flows through the detection area, the particles in it scatter or block light, and the instrument precisely calculates the number of particles of different particle sizes by analyzing changes in the light signal. The outer shell is mostly made of high - strength, oil - corrosion - resistant materials, and the internal optical and electronic components are specially treated to adapt to the oil environment. Its advantage lies in its high detection accuracy, capable of detecting tiny particles; fast detection speed, enabling real - time online detection; and little impact on oil performance. It is widely used in fields such as hydraulic systems, lubrication systems, and power transmission systems to ensure the normal operation of equipment and extend the service life of equipment.

Send your inquiry

HVAC Monitoring Equipments In Pharmaceutical Industry: Precision, Compliance And Contamination Control

In the pharmaceutical industry. In drug manufacturing, filling lines, cleanrooms and laboratory spaces, air is not simply a background element, it is an active variable that directly influences product quality, batch integrity and compliance with regulations. HVAC monitoring is not just a best practice in pharmaceutical industry settings. It is a fundamental requirement.
of cleanroom energy is HVAC
pressure cascade minimum
energy vs commercial buildings
to go-live, on-prem
Whymatter
Why HVAC monitoring is critical in pharma
The pharmaceutical production environment is subject to a strict set of constraints that have no equivalent in most other industries. Airborne particles, microbiological contamination, pressure differentials between zones, temperature deviations and humidity fluctuations can all compromise sterility, stability and the chemical integrity of active ingredients.

Regulatory frameworks such as EU GMP (Good Manufacturing Practice), FDA 21 CFR Part 11, ISO 14644 for cleanroom classification and PIC/S guidelines require documented, continuous environmental monitoring. Even a single undetected anomaly in air handling can result in batch rejection, regulatory warning letters or, in the worst case, a full facility shutdown.
HVAC Monitoring Solution For Sterility Assurance

1. HEPA Filtration Integrity

HEPA filter integrity is the primary mechanical control maintaining ISO classification. A pinhole leak exceeding 0.01% of upstream aerosol concentration constitutes filter failure under ISO 14644-3, regardless of the filter's installation age or supplier certificate.


2. Temperature & Humidity Control

Temperature and relative humidity are directly impact HEPA filter performance, microbial growth risk, electrostatic discharge (ESD), and product stability. EU GMP Annex 1 (2022) requires temperature and humidity to be continuously monitored and within validated specification before any classified manufacturing operation begins.


3. Particle Count Verification

Particle count verification is the primary method of confirming and maintaining ISO classification. ISO 21501-4 specifies the instrument standard for particle counters used in classification testing.

ISO Cleanroom Classification Reference — HVAC Compliance Parameters


ISO Class GMP Grade (EU) Max Particles / m³ (≥0.5 µm) Typical ACH Typical Application Requalification Frequency
ISO 5 Grade A/B 3,520 240-480 Aseptic filling, open product Every 6 months
ISO 6 Grade B (background) 35,200 150-240 Aseptic processing background Every 6 months
ISO 7 Grade C 352,000 40-60 Sterile compounding, device assembly Every 12 months
ISO 8 Grade D 3,520,000 10-25 Support areas, API handling, R&D labs Every 12 months
HVAC Monitoring Test


Compliance Task ISO 5/6 (Grade A/B) ISO 7/8 (Grade C/D) Governing Standard
Differential pressure monitoring Continuous + daily manual check Continuous + daily manual check EU GMP Annex 1 / ISO 14644-4
Temperature & humidity monitoring Continuous Continuous EU GMP Annex 1 / FDA 21 CFR 211.42
HEPA filter integrity test (PAO/DEHS) Every 6 months Annually ISO 14644-3 / EU GMP Annex 1
ISO classification particle count test Every 6 months Annually ISO 14644-2
Airflow velocity and ACH verification Every 6 months Annually ISO 14644-3
Pressure differential qualification test Every 6 months Annually ISO 14644-3 / ISO 14644-4
Recovery time test At requalification At requalification EU GMP Annex 1 (15-20 min target)
T&RH sensor calibration (NIST-traceable) Every 6-12 months Annually FDA 21 CFR 211.68
Particle counter calibration (ISO 21501-4) Annually minimum Annually minimum ISO 21501-4 / FDA 21 CFR 211.68
Core HVAC Monitoring Instruments
  1. Airborne Particle Counters (Online & Portable): Measure the concentration of microscopic particles in cleanroom air (such as the R320 or LPC series) to verify ISO cleanroom grades

  2. Anemometers and Air Velocity Meters: Measure air flow rates, face velocities, and air change effectiveness (such as the WS-40 digital anemometer).

  3. Filter Integrity Testing Instruments: Evaluate HEPA and critical filtration systems for leaks or bypass (such as the FIT-600 or V10 filter integrity testers).

  4. Total Organic Carbon (TOC) Analyzers: Assess cleanroom water for injection (WFI) and purity (such as the TA-2.6 Carbonanalyzer).

  5. Liquid Particle Counters: Count suspended particles in injectable solutions and purified water systems (such as the LPC-16DA and LPC-6CE).
Request a Quote Today
Our sales representatives are here to help you find the right instrument for your application.
Request a quote today to find the product you need with expert assistance.

Sterility assurance monitoring solution is a critical aspect of ensuring safety and quality in the medical device and pharmaceutical industries. By implementing robust sterility assurance protocols and utilizing high-precision cleanroom monitoring equipments for pharmaceutical manufacturing, companies can prevent microbial contamination and protect patient health. Maintaining a sterile environment throughout the manufacturing process is essential to meet the highest quality standards and ensure the safety of healthcare professionals and patients. By prioritizing sterility assurance, companies can uphold their commitment to delivering safe and reliable products.

Contact us
Now let's talk about the product you want.
Zetron is a global leader in HVAC cleanroom monitoring solutions for pharmaceutical manufacturing, combining innovative engineering with strict regulatory compliance and energy-efficient design. Our systems are trusted in sterile and non-sterile facilities worldwide, ensuring environmental control and process reliability from R&D to aseptic production.
  Professional feedback within 8 hour
  Full capabilities to rely on
  Best possible prices for you
  Fast prototype in 1 week
  Fast delivery in 10 days
Get in touch or visit us
+86 15699785629
Operating hours
Monday - Saturday(GMT+8): 8am - 8pm

Zetron delivers innovative solutions that boost efficiency and drive growth for your business success.

Contact with us
Contact person: Lisa Niu
WhatsApp:+86 15699785629
Add: