Zetron Instrument focuses on providing customized solutions for precision analysis and monitoring.
The dew point meter is used to measure the water vapor content in gases and determine the dew - point temperature of the gases. Based on principles such as the chilled mirror principle or the capacitance principle, it precisely controls the cooling process or detects capacitance changes to accurately measure the temperature at which the gas reaches saturation and condenses. The outer shell is generally made of sturdy and durable materials, and the internal optical or electronic components are carefully designed and calibrated to ensure measurement accuracy. Its advantage lies in its high measurement accuracy, capable of detecting tiny temperature changes; a wide measurement range suitable for gases under different humidity conditions; and good stability with reliable performance over long - term use. It is widely used in fields such as compressed air systems, natural gas pipelines, and air - conditioning systems to help users understand the water content in gases and prevent problems such as equipment corrosion and pipeline blockage.
1. HEPA Filtration Integrity
HEPA filter integrity is the primary mechanical control maintaining ISO classification. A pinhole leak exceeding 0.01% of upstream aerosol concentration constitutes filter failure under ISO 14644-3, regardless of the filter's installation age or supplier certificate.
2. Temperature & Humidity Control
Temperature and relative humidity are directly impact HEPA filter performance, microbial growth risk, electrostatic discharge (ESD), and product stability. EU GMP Annex 1 (2022) requires temperature and humidity to be continuously monitored and within validated specification before any classified manufacturing operation begins.
3. Particle Count Verification
Particle count verification is the primary method of confirming and maintaining ISO classification. ISO 21501-4 specifies the instrument standard for particle counters used in classification testing.
| ISO Class | GMP Grade (EU) | Max Particles / m³ (≥0.5 µm) | Typical ACH | Typical Application | Requalification Frequency |
| ISO 5 | Grade A/B | 3,520 | 240-480 | Aseptic filling, open product | Every 6 months |
| ISO 6 | Grade B (background) | 35,200 | 150-240 | Aseptic processing background | Every 6 months |
| ISO 7 | Grade C | 352,000 | 40-60 | Sterile compounding, device assembly | Every 12 months |
| ISO 8 | Grade D | 3,520,000 | 10-25 | Support areas, API handling, R&D labs | Every 12 months |
| Compliance Task | ISO 5/6 (Grade A/B) | ISO 7/8 (Grade C/D) | Governing Standard |
|---|---|---|---|
| Differential pressure monitoring | Continuous + daily manual check | Continuous + daily manual check | EU GMP Annex 1 / ISO 14644-4 |
| Temperature & humidity monitoring | Continuous | Continuous | EU GMP Annex 1 / FDA 21 CFR 211.42 |
| HEPA filter integrity test (PAO/DEHS) | Every 6 months | Annually | ISO 14644-3 / EU GMP Annex 1 |
| ISO classification particle count test | Every 6 months | Annually | ISO 14644-2 |
| Airflow velocity and ACH verification | Every 6 months | Annually | ISO 14644-3 |
| Pressure differential qualification test | Every 6 months | Annually | ISO 14644-3 / ISO 14644-4 |
| Recovery time test | At requalification | At requalification | EU GMP Annex 1 (15-20 min target) |
| T&RH sensor calibration (NIST-traceable) | Every 6-12 months | Annually | FDA 21 CFR 211.68 |
| Particle counter calibration (ISO 21501-4) | Annually minimum | Annually minimum | ISO 21501-4 / FDA 21 CFR 211.68 |
Sterility assurance monitoring solution is a critical aspect of ensuring safety and quality in the medical device and pharmaceutical industries. By implementing robust sterility assurance protocols and utilizing high-precision cleanroom monitoring equipments for pharmaceutical manufacturing, companies can prevent microbial contamination and protect patient health. Maintaining a sterile environment throughout the manufacturing process is essential to meet the highest quality standards and ensure the safety of healthcare professionals and patients. By prioritizing sterility assurance, companies can uphold their commitment to delivering safe and reliable products.