OPC-P50 portable oil particle counter is an instrument specially developed for oil pollution level detection according to national and international standards such as GB/T 18854-2002 (ISO11171-1999). 
5.0
design customization

    oops...!

    no product data.

    Go to homepage
    图片12 (6)

    Product Description

    OPC-P50 portable oil particle counter is an instrument specially developed for oil pollution level detection according to national and international standards such as GB/T 18854-2002 (ISO11171-1999). It is suitable for on-site and laboratory pollution detection of hydraulic oil, lubricating oil, shale oil, transformer oil (insulating oil), turbine oil (turbine oil), gear oil, engine oil, aviation kerosene, water-based hydraulic oil, phosphate ester oil and other oils. It can also be installed on various hydraulic transmission, oil filter, cleaning machine, test bench and other systems to realize online detection of system oil cleanliness. It can be widely used in aerospace, electric power, petroleum, chemical industry, transportation, port, metallurgy, machinery, automobile manufacturing and other fields.


    Features

    Portable Oil Particle Counter OPC-P50 3 Adopting the principle of light blocking (shading) method and using high-precision laser sensor, it has small size, high precision and stable performance.

    Portable Oil Particle Counter OPC-P50 4 Suitable for laboratory or on-site testing, it can also be equipped with a pressure reducing device for online high-pressure measurement and real-time monitoring of particle contamination in the oil system

    Portable Oil Particle Counter OPC-P50 5 Can be connected to an external pressure chamber to form positive/negative pressure, enabling detection and sample degassing of high viscosity samples

    Portable Oil Particle Counter OPC-P50 6 Built-in data analysis system, which can display the real data of particle size in each channel and automatically determine the sample grade

    Portable Oil Particle Counter OPC-P50 7 The pipeline is made of 316L and PTFE materials to meet the detection of various organic solvents and oils.

    Portable Oil Particle Counter OPC-P50 8 It has volume flushing and time flushing modes, which is convenient for users to use and maintain the equipment

    Portable Oil Particle Counter OPC-P50 9 Built-in ISO4406, NAS1638, SAE4059 (integral and differential), GJB420A, GJB420B, Г OCT17216 , GB/T14039 and other particle pollution level standards

    Portable Oil Particle Counter OPC-P50 10 Built-in calibration function, can be calibrated according to GB / T21540 , ISO4402, GB / T 18854 and other standards

    Portable Oil Particle Counter OPC-P50 11 Built-in data analysis system, which can automatically determine the sample grade according to the standard, and has the function of automatic data processing and printing

    Portable Oil Particle Counter OPC-P50 12 Built-in water sensor and temperature sensor

    Portable Oil Particle Counter OPC-P50 13 Chinese and English bilingual, one-touch switching, with printing and storage functions, 1 0.2 -inch large screen, easy and fast operation

    Portable Oil Particle Counter OPC-P50 14 Large storage capacity, can be stored in the instrument or external storage device

    Portable Oil Particle Counter OPC-P50 15 Embedded design , high-strength shell, easy to carry, suitable for all kinds of engineering machinery

    图片13 (4)
    图片13 (4)
    图片14 (4)
    图片14 (4)

    Functional parameters

    Light source  semiconductor laser
    Offline detection speed  5-60mL/min
    Offline sample viscosity  ≤100cSt (optional pressure chamber for high viscosity)
    Online detection pressure  0.1 -0.6Mpa (optional pressure reducing device with maximum pressure up to 42Mpa)
    Particle size range  1-500μm
    Interface  USB interface, power interface
    Data storage  Provides 1,000 sets of data storage space and supports USB storage
    Sensitivity  0.8μm or 4μm (c) 
    Limit coincidence error  40,000 particles/ml
    Counting volume  1-999 ml
    Counting accuracy  error less than ±10%
    Protection level   IP 67
    Test time interval  1 second - 24 hours
    Detection sample temperature  0-80℃
    Water activity reference value  0-1aw (±0.05aw)
    Water content  0-360ppm (±10%)
    Working temperature  -20-60℃
    Charging  DC12.6V AC100~240V
    Weight  5.5kg
    Screen size  10.2 inches
    Battery capacity  8000mAh
    Volume  365×295×170mm

    Application Scenarios

    图片4 (15)
    Contact us
    Get in touch with us
    Just leave your email or phone number in the contact form so we can send you a free quote for our wide range of designs!
    Related Products
    no data
    +86 15699785629
    Operating hours
    Monday - Saturday(GMT+8): 8am - 8pm

    Zetron delivers innovative solutions that boost efficiency and drive growth for your business success.

    Contact with us
    Contact person: Lisa Niu
    WhatsApp:+86 15699785629
    Add:

    Office 19B, 17th Floor, Building 1, 48 Dongzhimenwai Avenue, Dongcheng District, Beijing

    Copyright © 2026 Zetron - www.bjzetron.com | Sitemap  | Privacy Policy
    Contact us
    wechat
    phone
    email
    whatsapp
    Contact customer service
    Contact us
    wechat
    phone
    email
    whatsapp
    cancel
    Customer service
    detect