loading

Zetron Instrument focuses on providing customized solutions for precision analysis and monitoring.

Portable liquid cleanliness testing 1
Portable liquid cleanliness testing 1

Portable liquid cleanliness testing

For laboratory bottles and industrial fluid systems
SUITABLE FOR TESTING FLUIDS SUCH AS
OM-11, OM-15 AND ATF K-60
5.0
design customization

    oops...!

    no product data.

    Go to homepage

    Offline and online liquid cleanliness analysis

    Portable liquid cleanliness testing 2
    1–600 μm
    DETECTION RANGE
    Portable liquid cleanliness testing 3
    30 s
    TEST TIME
    啊
    128
    CHANNELS
    11111
    7 in
    ANDROID DISPLAY
    图片16 (6)

    Lab and online liquid

    cleanliness testing

    OPC-6 supports direct bottle sampling, optional pressure bottle sampling and continuous online measurement. It measures particle contamination in laboratory samples and industrial hydraulic, lubrication, filtration and test systems.

    Complete liquid particle analysis

    Portable liquid cleanliness testing 7
    01
    Multiple sampling modes
    Direct bottle, pressure bottle and continuous online measurement configurations.
    Portable liquid cleanliness testing 8
    02
    Standards and calibration
    Built-in cleanliness standards with ACFTD, ISO MTD and GOST curves.
    图片1 (29)
    03
    128 measurement channels
    Particle sizes can be configured in 0.1 μm increments for custom analysis.
    787
    04
    Reports and connectivity
    6 GB storage, USB export, built-in printing, RS232, RS485 and LAN.

    Workflow

    Portable liquid cleanliness testing 11
    01
    Prepare
    Connect bottle or line
    Portable liquid cleanliness testing 12
    02
    Select
    Choose mode and standard
    图片1 (29)
    03
    Measure
    Run the 30 s test
    787
    04
    Report
    Print or export results

    Fluid suitability

    Portable liquid cleanliness testing 15
    01
    OM-11
    Liquid cleanliness testing
    Portable liquid cleanliness testing 16
    02
    OM-15
    Liquid cleanliness testing
    图片1 (29)
    03
    ATF K-60
    Transmission fluid testing
    787
    04
    Industrial fluids
    Hydraulic and lubrication oils

    Core capability

    Portable liquid cleanliness testing 19
    01
    1 to 600 μm
    Sensor-dependent range
    Portable liquid cleanliness testing 20
    02
    128 channels
    0.1 μm size increments
    图片1 (29)
    03
    30 s per test
    Fast routine measurement
    787
    04
    5 to 60 mL/min
    Measurement and cleaning
    图片1 (29)
    05
    Android interface
    7-inch color touchscreen

    Suitable fluids

    Suitable for testing fluids such as OM-11, OM-15 and ATF K-60.

    图片17 (6)

    Technical specifications

    Performance and configuration data supplied for OPC-6.

    Parameter

    Specification

    Parameter

    Specification

    Light source

    Semiconductor laser

    Offline sample viscosity

    ≤100 cSt, up to 400 cSt with pressure bottle sampler

    Detection range

    1 to 600 μm, sensor dependent

    Online pressure

    0.1 to 0.6 MPa, up to 40 MPa with pressure reducer

    Sensitivity

    1 μm (ISO 4402), 4 μm(c) (GB/T 18854 / ISO 11171)

    Online interval

    1 s to 10 h 59 min 59 s

    Sampling mode

    Offline or online

    Sample temperature

    0 to 80 °C

    Sample volume accuracy

    Better than ±3%

    Operating temperature

    −20 to 60 °C

    Measurement time

    30 s per test

    Storage temperature

    −30 to 80 °C

    Measurement flow

    5 to 60 mL/min, default 20 mL/min

    Power supply

    100 to 265 VAC, 24 VDC or lithium battery

    Cleaning flow

    5 to 60 mL/min, default 20 mL/min

    Sample volume

    10 to 100 mL per test

    Flush volume

    0 to 90 mL in 1 mL increments

    Channels

    128, size settings in 0.1 μm increments

    Coincidence limit

    10,000 to 40,000 particles/mL, sensor dependent

    Display

    7-inch Android color touchscreen

    Count repeatability

    RSD <2%

    Dimensions

    410 × 330 × 170 mm

    Relative count error

    ±10%

    Net weight

    7 kg

    Specifications depend on the selected sensor and accessories.

    Confirm the final configuration before ordering.

    Contact us
    Get in touch with us
    Just leave your email or phone number in the contact form so we can send you a free quote for our wide range of designs!
    Related Products
    +86 15699785629
    Operating hours
    Monday - Saturday(GMT+8): 8am - 8pm

    Zetron delivers innovative solutions that boost efficiency and drive growth for your business success.

    Contact with us
    Contact person: Lisa Niu
    WhatsApp:+86 15699785629
    Add:

    Office 19B, 17th Floor, Building 1, 48 Dongzhimenwai Avenue, Dongcheng District, Beijing

    Copyright © 2026 Zetron - www.bjzetron.com | Sitemap  | Privacy Policy
    Contact us
    wechat
    phone
    email
    whatsapp
    Contact customer service
    Contact us
    wechat
    phone
    email
    whatsapp
    cancel
    Customer service
    detect