loading

Zetron Instrument focuses on providing customized solutions for precision analysis and monitoring.

Zetorn MIC600OZ Rack-mounted ozone gas concentration analyzer 1
Zetorn MIC600OZ Rack-mounted ozone gas concentration analyzer 2
Zetorn MIC600OZ Rack-mounted ozone gas concentration analyzer 3
Zetorn MIC600OZ Rack-mounted ozone gas concentration analyzer 4
Zetorn MIC600OZ Rack-mounted ozone gas concentration analyzer 5
Zetorn MIC600OZ Rack-mounted ozone gas concentration analyzer 6
Zetorn MIC600OZ Rack-mounted ozone gas concentration analyzer 1
Zetorn MIC600OZ Rack-mounted ozone gas concentration analyzer 2
Zetorn MIC600OZ Rack-mounted ozone gas concentration analyzer 3
Zetorn MIC600OZ Rack-mounted ozone gas concentration analyzer 4
Zetorn MIC600OZ Rack-mounted ozone gas concentration analyzer 5
Zetorn MIC600OZ Rack-mounted ozone gas concentration analyzer 6

Zetorn MIC600OZ Rack-mounted ozone gas concentration analyzer

The exhaust ozone detector calculates the current ozone concentration value by measuring the change in light signal intensity before and after the absorption of UV light by ozone. We can offer OEM/ODM service.

5.0
design customization

    oops...!

    no product data.

    Go to homepage

    UVOZ-3000 Exhaust Ozone Detector 

    The exhaust ozone detector calculates the current ozone concentration value by measuring the change in light signal intensity before and after the absorption of UV light by ozone. The equipment uses a dual-optical UV light source system with a lamp intelligent management system inside, which can make the UV lamp quickly reach the measurement state after power on. Using foreign separated light cell technology, the equipment has the characteristics of no leakage, high pressure resistance, high flow sampling gas impact resistance, easy cleaning, easy maintenance, simple operation and low cost of use.

    It is mainly used for continuous detection of ozone gas in various industrial environments, and can also be used to detect ozone gas in operating pipelines, containers and other environments, and is widely used in pharmaceutical, chemical, municipal and wastewater treatment industries for ozone generator outlet concentration and ozone generator output measurement.


    Ozone analyzer with touch screen operation interface, real-time display of ozone gas concentration, with pressure and temperature compensation and display, automatic zero time and manual zero mode can be set. High concentration (g/Nm3) range with flow input function, real-time display of ozone generator output. With two sets of relay signal output, users can freely choose the high alarm point and low alarm point signal output connection. The core component adopts UV long life light source system with high transmittance quartz sheet to ensure the stability of the zero point and prevent the zero point drift from affecting the accuracy of the detection concentration.


    According to the foreign light cell technology design pressure-resistant, impact-resistant independent light cell structure, the gas flow, pressure and flow rate remain unchanged during the operation of the calibration zero, to prevent the impact of airflow on the calibration zero, no need to close the ozone intake can complete the calibration zero operation, to ensure that the equipment can operate continuously 24 hours a day.

    Zetorn MIC600OZ Rack-mounted ozone gas concentration analyzer 7


    Tag: Exhaust ozone detector, Ozone detectorOzone concentration online monitor, Ozone generator manufacturer, Tabletop ozone analyzer, OEM/ODM services

    Sampling method Positive pressure sampling ,  Negative pressure sampling
    Content interface Ozone concentration ,  Temperature compensation ,  Pressure compensation
    Light source life About 30000-50000 hours
    Display interface 4.3 inch touch screen operation interface
    Auxiliary functions Temperature compensation, pressure compensation
    Sampling flow rate 0.5L±0.2L/min
    Input pressure <0.1MPa
    Concentration error < 2%FS
    Linearity error  < 2%FS
    Zero point drift  <±0.8%.FS
    Response time  0.03 seconds for signal, 0.3 seconds for display
    Ambient temperature  -20~50℃.
    Sampling interface  Bypass sampling Φ6 (6*4mm quick screw interface) ,  Tandem sampling Φ8 (8*6mm quick screw interface)
    Communication mode RS-485
    Output mode 4-20mA(active)
    Relay signal High alarm point signal, low alarm point signal.
    Input power  AC 110-220V.
    Instrument size 133mm (H) × 482mm (W) × 300mm (D), 19" 3U chassis.
    Free warranty Light source free warranty for 2 years; host free warranty for 2 years (except for oil, water, improper use)
    Standard configuration Anti-corrosion flow meter , intake filter , ozone exhaust gas destroyer , negative pressure suction air pump

    Application areas: ozone generator manufacturers, municipal water industry, industrial wastewater industry, fine chemical industry, food and drinking water industry, space disinfection industry, pool disinfection industry, flavor synthesis industry and other industries using ozone generator.

    Zetorn MIC600OZ Rack-mounted ozone gas concentration analyzer 8

    Sorry  There is no "Application", you can view other services。

    Contact us
    Get in touch with us
    Just leave your email or phone number in the contact form so we can send you a free quote for our wide range of designs!
    Related Products
    no data
    +86 15699785629
    Operating hours
    Monday - Saturday(GMT+8): 8am - 8pm

    Zetron delivers innovative solutions that boost efficiency and drive growth for your business success.

    Contact with us
    Contact person: Lisa Niu
    WhatsApp:+86 15699785629
    Add:

    Office 19B, 17th Floor, Building 1, 48 Dongzhimenwai Avenue, Dongcheng District, Beijing

    Copyright © 2025 Zetron - www.bjzetron.com | Sitemap  | Privacy Policy
    Customer service
    detect