Zetron Instrument focuses on providing customized solutions for precision analysis and monitoring.
MIC-600 online composite gas detector is used for 24-hour continuous online monitoring of multiple gas concentrations and temperature and humidity measurement, on-site display of concentration and sound and light alarm for exceeding the standard, and remote data transmission. We provide gas detector OEM/ODM serves.
|
Gases to be detected
|
Range
|
Accurancy
|
Resolution
|
Response time T90
|
|
Ammonia gas ( NH3 )
|
0-100ppm
|
<±2%(F.S)
|
0.01ppm
|
≤30 seconds
|
|
Combustible gas ( EX )
|
0-100%LEL
|
<±2%(F.S)
|
0.1%LEL
|
≤10 seconds
|
|
Methane ( CH4 )
|
0-100%Vol
|
<±2%(F.S)
|
0.1%Vol
|
≤10 seconds
|
|
Oxygen gas ( O2 )
|
0-30%Vol
|
<±2%(F.S)
|
0.01%Vol
|
≤10 seconds
|
|
Nitrogen gas ( N2 )
|
0-100%Vol
|
<±2%(F.S)
|
0.01%Vol
|
≤10 seconds
|
|
Hydrogen sulfide ( H2S )
|
0-100ppm
|
<±2%(F.S)
|
0.01ppm
|
≤30 seconds
|
|
Sulfur dioxide ( SO2 )
|
0-100ppm
|
<±2%(F.S)
|
0.01ppm
|
≤30 seconds
|
|
Nitric oxide ( NO )
|
0-100ppm
|
<±2%(F.S)
|
0.01ppm
|
≤30 seconds
|
|
Nitrogen dioxide ( NO2 )
|
0-100ppm
|
<±2%(F.S)
|
0.01ppm
|
≤25 seconds
|
Tag: Fixed gas detector、 Online composite gas detector、Multiple gas concentrations monitor、Nitrogen gas detector、 Online Toxic and Harmful Gas Detector、Electrochemical gas monitor、OEM/ODM gas analyzer
| Detection gas |
Composite gas (carbon monoxide CO, hydrogen sulfide H2S, oxygen O2, combustible gas Ex) |
| Optional |
Can detect any 4 to 6 kinds of gases and temperature and humidity at the same time |
| Detection range |
CO (0~1000ppm), H2S (0~100ppm), O2 (0~30%Vol), Ex (0~100%LEL), other ranges can be customized |
| Resolution |
CO(0.1ppm), H2S(0.01ppm), O2(0.01%Vol), Ex(0.1%LEL), higher resolution can be customized |
| Detection principle |
Electrochemistry, catalytic combustion, infrared, thermal conductivity, PID photoion , depending on gas, range, site environment and user needs |
| Sensor life |
2 to 3 years for electrochemical principle, 2 years or 6 years for oxygen, 5 to 10 years for infrared principle, 3 years for catalytic combustion, and 5 years for thermal conductivity |
| Temperature detection |
-40℃~+120℃ (optional), humidity detection: 0~100%RH (optional), resolution : temperature 0.1℃, humidity: 1%RH |
| Detection accuracy |
≤±2%FS (≤2% in full scale), temperature 0.5℃, humidity: 3%RH, higher precisio n can be customized |
| Working mode |
Fixed installation, online detection, diffusion measurement, pipeline type, flow type , pump suction type optional |
| Installation method |
Pipeline type, wall-mounted type. The working pressure of the pipeline type is ±30% of atmospheric pressure, and it needs to be depressurized if it exceeds the range. |
| Response time | T90≤20 seconds |
| Recovery time | ≤30 seconds |
| Output signal |
Bus system RS485 (RTU), optional three (four) wire system 4~20mA, 0~20mA, 1~5V, 0~5V, 0~10V, wireless transmission |
| Alarm mode |
On-site sound and light alarm (optional), default 1 channel, optional 3 channels of passive contact (dry node) output, three-level alarm, alarm point can be set |
| Working environment | -40℃~+70℃ |
| Sample gas temperature |
-40℃~+70℃ (regular), optional: -40℃~+400℃, -40℃~+800℃ (high 1300℃) |
| Relative humidity | ≤10-95%RH (regular) non-condensing occasions, optional: 10-99%RH for high temperature and high humidity occasions, when ordering |
| Working voltage |
12~30V (DC DC, the standard power supply of a single device is 24V, 1A or more than 1A DC switching power supply) |
| Explosion-proof form | Flameproof ExdⅡCT6 |
| Dimensions | 210×170×85mm |
| Weight | 1.8Kg |
Application occasions: petroleum, chemical, pharmaceutical, environmental protection, flue gas analysis, air treatment and other occasions that require fixed installation and online gas concentration detection.