MS600 Portable CO Analyzer Explosion Proof Type Inner Pump

It includes sound & light alarm, vibration alarm, display screen visual alarm.Alarm types include: concentration alarm, under-voltage alarm, and failure alarm. Multiple alarm mode settings: low alarm, high alarm, interval alarm, and weighted average alarm.

Details

Zetron MS600 CO Gas Detector Monitor

Graphical display, and use the form of curve to reflect the trend of gas concentration changes in a certain period of time. Data recovery function; in case of mis-operation, it is possible to select partial or full recovery. It is possible to set whether to display the maximum value, minimum value, average value or not. Standard USB charging port, with charging protection function, USB hot-plug supported, and the charging status instrument can work properly. 4600mA high capacity rechargeable polymer battery is adopted, so it is possible to work for a long period of time. High-precision temperature and humidity measurements (optional configuration).


Gases to be detected
Range
Accurancy
Resolution
Hydrogen sulfide ( CO )
0-500ppm
<±2%(F.S)
0.01ppm
Sulfur dioxide ( SO2 )
0-100ppm
<±2%(F.S)
0.01ppm
Nitric oxide ( NO )
0-100ppm
<±2%(F.S)
0.01ppm
Nitrogen dioxide ( NO2 )
0-100ppm
<±2%(F.S)
0.01ppm
Nitrogen oxide ( NOX )
0-100ppm
<±2%(F.S)
0.01ppm
Carbon disulfide ( CS2 )
0-50ppm
<±2%(F.S)
0.01ppm
Acrylonitrile ( C3H3N )
0-50ppm
<±2%(F.S)
0.01ppm
Iodine gas ( I2 )
0-50ppm
<±2%(F.S)
0.01ppm
Note: Not all gases and range are listed, if you need more information, please contact us.





Parameter

Detection principle
Electrochemical, catalytic combustion, infrared, thermal conductivity,
PID photoionization, and so on.
Depending on the type of gas, range, field environment and user demand.
Sensor service life
Electrochemical principle: 2 ~ 3 years; 
Oxygen gas: 2 years or 6 years can be selected; 
Infrared principle: 5 ~ 10 years;
Catalytic combustion: 3 years; 
Thermal conductivity: 5 years; 
PID photoionization: 2 ~ 3 years.
Allowable error
≤±1% F.S (other precision levels can be customized)
Linearity
≤±1%
Repeatability
≤±1%
Uncertainty
≤±1%
Response time
T90≤20 seconds
Recovery time
≤30 seconds
Working environment
Temperature: -40 ℃ ~ + 70 ℃, humidity: ≤10 ~ 95% RH, and built-in filters can be used in high humidity or high dust environment.
Sample gas temperature
-40 ℃ ~ + 70 ℃, and the optional configuration of high-temperature sampling and cooling filter handle will be possible to detect the smoke gas at the temperature of 1300 ℃.

Application

All the cases which requires the portable rapid detection of gas concentrations such as petroleum, chemical, pharmaceutical, environmental protection, combustion gas distribution, warehousing, smoke gas analysis, air governance, and so on.