Beijing Zetron Technology Co., Ltd

info@bjzetron.com CN

MS400 Portable 4 in 1 Gas Detector

The MS400 measures up to 4 gases, including toxic, flammable gases and vapors, and oxygen all at once—either in pump or diffusion mode. Innovative signaling design and handy wizard functions ensure complete safety throughout the process. We provide gas detector OEM/ODM serves.

Details

MS400 Portable 4 in 1 Gas Detector

MS400 Series Gas Detector is up to 4 potential atmospheric hazards including oxygen, combustible and toxic gases, t he types of gases for detection are more than 500 types,MS400 is unparalleled in its versatility, capability and overall value.

It's adopted water-resistant line of portable gas detectors has transformed the market with its matchless array of features.


Continuously monitoring and displaying concentrations of up to 4 gases, the compact and lightweight MS400 was designed and engineered with an extensive host of applications in mind.  

Gases to be detected  Range  Minimum reading Response time T90
Combustible gas ( EX )   0-100%LEL   0.1%LEL  ≤10 seconds
Methane ( CH4 )  0-100%LEL   0.1%LEL  ≤10 seconds
Oxygen gas ( O2 )  0-30%Vol   0.01%Vol  ≤10 seconds
Carbon monoxide ( CO )  0-100ppm  0.1ppm  ≤25 seconds
Carbon dioxide ( CO2 )  0-500ppm  1ppm ≤20 seconds
Ozone ( O3 ) 0-1ppm  0.001ppm ≤20 seconds
Hydrogen sulfide ( H2S )  0-10ppm 0.001ppm ≤30 seconds
Sulfur dioxide ( SO2 )  0-10ppm 0.001ppm ≤30 seconds
Nitric oxide ( NO ) 0-10ppm 0.001ppm ≤30 seconds
TotalVolatileOrganic 
Compound gases 
( TVOC )
0-10ppm 0.001ppm ≤30 seconds
Volatile gases ( PID )  0-10ppm 0.001ppm ≤30 seconds


Tag: Pump gas monitor, Multi gas detector , Gas leak detector, Gas alarm detector, Hydrogen gas analyzer, phosphine detector, Methane leak monitor, OEM/ODM gas detector

Parameter

Measuring gas
Hydrogen sulfide (H2S)
Carbon monoxide (CO)
Oxygen (O2)
Sulfur dioxide (SO2)
Measuring range
H2S:0-100000ppm
CO:0-10000ppm
O2:0-100%Vol
SO2:0-10000ppm
and other ranges can be customized
Resolution
0.01 ppm
1 ppm
 0.01 %Vol
0.1 %Vol
Other resolution can be customized
Sensor type
Infrared Sensor
Other Sensor:Laser , Electrochemical, Thermal conductivity, catalytic combustion, thermal conductivity, PID photoionization, and so on.
Depending on the type of gas, range, field environment and user demand,
Other sensors can be  customized.
Measuring type
Built-in Pump sunction
Response time
T90<30s
Display
2.31-inch high-definition color screen
Alarm method
sound & light alarm; 
vibration alarm;  
sound & light + vibration alarm;
turning off the alarm
Battery
DC3.7V,   4500mA high capacity rechargeable polymer battery
Data storage
Standard capacity is 100, 000 entries
Working temperature
-40 ℃ ~ + 70 ℃
Working humidity
≤10 ~ 95% RH
Housing
Rubber enclosure
Standard accessories
Manual, qualification certificate, warranty card, USB charger (including the data cable), belt clip, colorful packaging box (optional high-grade aluminum instrument case)
Dimension
160×70×28mm (L×W×H)
 Weight
300g
Ex grade
 Ex ia IIC T6 Ga   Intrinsically safe type
Ingress protection
IP65

Application

All the cases which requires the portable rapid detection of gas concentrations such as petroleum, chemical, pharmaceutical, environmental protection, combustion gas distribution, warehousing, smoke gas analysis, air governance, and so on.

Video

Product
selection

Here are all the products you want
Search for matching products

Search products

More products