Beijing Zetron Technology Co., Ltd

info@bjzetron.com CN

MS600 Portable 6 in 1 Monitor

The MS600 measures up to 6 gases, including toxic, flammable gases and vapors, and oxygen all at once with internal pump and rechargeable battery. Innovative signaling design and handy wizard functions ensure complete safety throughout the process. We provide gas detector OEM/ODM serves.

Details

MS600 Portable 6 in 1 Monitor

MS600 Portable Multi Gas Detector can be used in: mobile rapid and accurate detection of a variety of gas concentration and measurement of environmental temperature and humidity, if the measurement exceeded the limit value, the alarm will sound with flash light.

It adopted advanced electric circuit design, mature kernel algorithm processing, unique external appearance design, had achieved a number of patents about the software works, external appearance, and so on. 


It is possible to simultaneously detect 1 ~ 6 types of gases, and the units can be switched freely. The types for detection are more than 500 types.

Gases to be detected  Range  Allowable Minimum reading Response time T90
Combustible gas ( EX )   0-100%LEL  <±2%(F.S)  0.1%LEL  ≤10 seconds
Methane ( CH4 )  0-100%LEL  <±2%(F.S)   0.1%LEL  ≤10 seconds
Oxygen gas ( O2 )  0-30%Vol  <±2%(F.S)  0.01%Vol  ≤10 seconds
Carbon monoxide ( CO )  0-100ppm  <±2%(F.S)  0.1ppm  ≤25 seconds
Carbon dioxide ( CO2 )  0-500ppm  <±2%(F.S)  1ppm ≤20 seconds
Ozone ( O3 ) 0-1ppm  <±2%(F.S)  0.001ppm ≤20 seconds
Hydrogen sulfide ( H2S )  0-10ppm <±2%(F.S)  0.001ppm ≤30 seconds
Sulfur dioxide ( SO2 )  0-10ppm <±2%(F.S)  0.001ppm ≤30 seconds
Nitric oxide ( NO ) 0-10ppm <±2%(F.S)  0.001ppm ≤30 seconds
TotalVolatileOrganic  0-10ppm <±2%(F.S)  0.001ppm ≤30 seconds
Compound gases 
( TVOC )
Volatile gases ( PID )  0-10ppm <±2%(F.S)  0.001ppm ≤30 seconds

Tag: Pump gas monitor, Multi gas detector , Gas leak detector, 6 in1 gas alarm detector, Nitric oxide gas analyzer, Electrochemical gas detector, Methane leak monitor, OEM/ODM gas detector.

Parameter


Gases to be detected
monitor up to 6 gases such as toxic gases, oxygen gas, carbon dioxide, inflammable and explosive gases, TVOC, and so on.Optional configuration: temperature and humidity measurements.
Application scenarios
All the cases which requires the portable rapid detection of gas concentrations such as petroleum, chemical, pharmaceutical, environmental protection, combustion gas distribution, warehousing, smoke gas analysis, air governance, and so on.
Detection range
0 ~ 1, 10, 100, 1000, 5000, 50000, 100000ppm, 200 mg/L, 100%LEL, 20%, 50%, 100%Vol, can be selected; and other ranges can be customized.
Resolution
 0.01ppm or 0.001ppm (0 ~ 10 ppm);
0.01ppm (0 ~ 100 ppm),
0.1ppm (0 ~ 1000 ppm),
1ppm (0 ~ 10000 ppm or more),
0.01 mg/l (0 ~ 200 mg/l),
0.1% LEL,
0.01%LEL
0.001% Vol
Detection principle
Electrochemical, catalytic combustion, infrared, thermal conductivity,
PID photoionization, and so on.
Depending on the type of gas, range, field environment and user demand.
Sensor service life
Electrochemical principle: 2 ~ 3 years; 
Oxygen gas: 2 years or 6 years can be selected; 
Infrared principle: 5 ~ 10 years;
Catalytic combustion: 3 years; 
Thermal conductivity: 5 years; 
PID photoionization: 2 ~ 3 years.
Allowable error
≤±1% F.S (other precision levels can be customized)
Linearity
≤±1%
Repeatability
≤±1%
Uncertainty
≤±1%
Response time
T90≤20 seconds
Recovery time
≤30 seconds
Working environment
Temperature: -40 ℃ ~ + 70 ℃, humidity: ≤10 ~ 95% RH, and built-in filters can be used in high humidity or high dust environment.
Sample gas temperature
-40 ℃ ~ + 70 ℃, and the optional configuration of high-temperature sampling and cooling filter handle will be possible to detect the smoke gas at the temperature of 1300 ℃.
Temperature and humidity measurement
Optional configuration: temperature at -40 ℃ ~ + 70 ℃, accuracy level at 0.5 ℃; humidity at 0 ~ 100% RH, precision level at 3 % RH
Power supply
3.6VDC, 6000mA high capacity rechargeable polymer battery
Display mode
2.5-inch high-definition color screen
Detection mode
Built-in pump-suction type measurement, and flow rate at 500 ml / min. Calibration flow rate should be greater than 500 ml / min,
three-way pipe should be connected, so as to ensure that the excessive gas will be discharged from the bypass
Alarm mode
It is possible to set as sound & light alarm, vibration alarm, sound & light + vibration alarm, turning off the alarm.
Communication interface
USB (charging and communication), optional: RS232, infrared communication, automatic recognition

Application

All the cases which requires the portable rapid detection of gas concentrations such as petroleum, chemical, pharmaceutical, environmental protection, combustion gas distribution, warehousing, smoke gas analysis, air governance, and so on.

Video

Sorry  There is no "Application", you can view other services。

Product
selection

Here are all the products you want
Search for matching products

Search products

More products