MS500 Portable 5 in 1 gas detector can detect gas concentrations in pipelines or confined spaces, atmospheric environments, gas leaks or various background gases such as ammonia or oxygen with high concentrations of single gas purity, and more than 500 types of gases. We provide gas detector OEM/ODM serves.

Details


MS500 Portable 5 in 1 gas detector

MS500 gas detector is used for portable and rapid detection of toxic and hazardous gas concentration, temperature and humidity measurement and alarm. It adopts 2.5-inch HD color screen to display the concentration in real time, and selects imported brands (Honeywell, Japan fundamental, UK City, UK Alpha, UK Dynament, Switzerland Membrapor, etc.) gas sensors, the main detection principles are: electrochemical, infrared, catalytic combustion, thermal conductivity, PID light ion. The MS500 can detect gas concentrations in pipelines or confined spaces, atmospheric environments, gas leaks or various background gases such as ammonia or oxygen with high concentrations of single gas purity, and more than 500 types of gases.

Gases to be detected  Range  Minimum reading Response time T90
Combustible gas ( EX )   0-100%LEL   0.1%LEL  ≤10 seconds
Methane ( CH4 )  0-100%LEL   0.1%LEL  ≤10 seconds
Oxygen gas ( O2 )  0-30%Vol   0.01%Vol  ≤10 seconds
Carbon monoxide ( CO )  0-100ppm  0.1ppm  ≤25 seconds
Carbon dioxide ( CO2 )  0-500ppm  1ppm ≤20 seconds
Ozone ( O3 ) 0-1ppm  0.001ppm ≤20 seconds
Hydrogen sulfide ( H2S )  0-10ppm 0.001ppm ≤30 seconds
Sulfur dioxide ( SO2 )  0-10ppm 0.001ppm ≤30 seconds
Nitric oxide ( NO ) 0-10ppm 0.001ppm ≤30 seconds

TotalVolatileOrganic 

Compound gases 

( TVOC )
0-10ppm 0.001ppm ≤30 seconds
Volatile gases ( PID )  0-10ppm 0.001ppm ≤30 seconds


Tag: Pump gas monitor, Five in one gas detector , Handheld gas leak detector, Gas alarm detector, Toxic and harmful gas analyzer, Carbon monoxide detector, Methane leak monitor, Portable gas alarm, OEM/ODM gas detector

Parameter

Gases to be detected
Arbitrary combination of 1 ~ 5 types of gases such as toxic gases, oxygen gas, carbon dioxide, inflammable and explosive gases,
TVOC, and so on.
Optional configuration: temperature and humidity measurements.

Application scenarios

All the cases which requires the portable rapid detection of gas concentrations such as petroleum, chemical, pharmaceutical,
environmental protection, combustion gas distribution, warehousing, smoke gas analysis, air governance, and so on.

Detection range

0 ~ 1, 10, 100, 1000, 5000, 50000, 100000ppm, 200 mg/L, 100%LEL, 20%, 50%, 100%Vol, can be selected; and other ranges can be customized.
Resolution
0.01ppm or 0.001ppm (0 ~ 10 ppm);
0.01ppm (0 ~ 100 ppm),
0.1ppm (0 ~ 1000 ppm),
1ppm (0 ~ 10000 ppm or more),
0.01 mg/l (0 ~ 200 mg/l),
0.1% LEL,
0.01%,
0.001% Vol
Detection principle
Electrochemical, catalytic combustion, infrared, thermal conductivity, PID photoionization, and so on, depending on the type of gas, range, field environment and user demand.
Sensor service life
Electrochemical principle: 2 ~ 3 years; Oxygen gas: 2 years or 6 years can be selected; infrared principle: 5 ~ 10 years; catalytic combustion: 3 years; thermal conductivity: 5 years; PID photoionization: 2 ~ 3 years.
Allowable error
≤±2% F.S (other or higher precision levels can be customized)
Linearity
≤±2%
Repeatability
≤±2%
Uncertainty
≤±2%
Response time
T90≤20 seconds
Recovery time
≤30 seconds
Working environment
Temperature: -40 ℃ ~ + 70 ℃, humidity: ≤10 ~ 95% RH, and built-in filters can be used in high humidity or high dust environment.

Sample gas temperature

-40 ℃ ~ + 70 ℃, and the optional configuration of high-temperature sampling and cooling filter handle will be possible to detect
the smoke gas at the temperature of 800 ℃ or higher.
Temperature and humidity measurement
Optional configuration: temperature at -40 ℃ ~ + 70 ℃, accuracy level at 0.5 ℃; humidity at 0 ~ 100% RH, precision level at 3 % RH
Power supply
3.6VDC, 5500mA high capacity rechargeable polymer battery
Detection mode
Built-in pump-suction type measurement, and flow rate at 500 ml / min. Calibration flow rate should be greater than 500 ml / min,
three-way pipe should be connected, so as to ensure that the excessive gas will be discharged from the bypass
Alarm mode
It is possible to set as sound & light alarm, vibration alarm, sound & light + vibration alarm, Turning off the alarm.
Communication interface
USB (charging and communication), optional: RS232, infrared communication, automatic recognition
Data storage
Standard configuration is the data storage capacity for 100, 000 entries
Protection level
IP66
Explosion-proof type
Intrinsically safe type
Explosion-proof mark
Exia II CT6
Exterior dimensions
180×78×33mm (L×W×H)
Weight
350g
Standard accessories
Manual, qualification certificate, warranty card, USB charger (including the data cable), high-grade aluminum instrument case,
belt clip, humidity dust filter
Optional items
Temperature and humidity measurement function, 1.2 m retractable sampling handle (1-10 meter hose, and the standard length is 1
meter), 0.4 meter stainless steel sampling handle (with dust filter, not retractable), high temperature sampling and cooling
filter handle, high temperature humidity pretreatment system, multiple humidity dust filter, hanging rope, CD-ROM (upper level
computer communication software), external mini wireless infrared printer

Application

All the cases which requires the portable rapid detection of gas concentrations such as petroleum, chemical, pharmaceutical, environmental protection, combustion gas distribution, warehousing, smoke gas analysis, air governance, and so on.


Video

Product
selection

Here are all the products you want
Search for matching products

Search products

More products