loading

Zetron Instrument focuses on providing customized solutions for precision analysis and monitoring.

Online particle counter LPC-M3 1
Online particle counter LPC-M3 1

Online particle counter LPC-M3

LPC-M3 online particle counter adopts the light resistance (shading) counting principle specified by the International Hydraulic Standards Committee, and is a device specially used for on-site online measurement of oil contamination level detection.
5.0
design customization

    oops...!

    no product data.

    Go to homepage

    Product Description

    LPC-M3 online particle counter adopts the light resistance (shading) counting principle specified by the International Hydraulic Standards Committee, and is a device specially used for on-site online measurement of oil contamination level detection. It has the advantages of small size, light weight, fast detection speed, high accuracy, good repeatability, etc., and can work under high temperature and high pressure and other harsh conditions. It is suitable for all light-transmitting solvents such as engine oil, gear oil, transformer oil (i.e. insulating oil), hydraulic oil, lubricating oil, synthetic oil, water-based (water-based hydraulic oil, water glycol, etc.), alcohols, ketones, etc., and can be widely used in aerospace, petrochemical, transportation ports, steel metallurgy, automobile manufacturing and other fields.

    Application Scenarios

    图片8 (4)

    Product Features

    Online particle counter LPC-M3 3 Adopting the principle of light blocking (light shielding) method and using high-precision laser sensor, it has small size, high precision and stable performance ;

    Online particle counter LPC-M3 4 Suitable for on-site online detection, it can monitor the particle contamination in the oil system in real time ;

    Online particle counter LPC-M3 5 Built-in data analysis system, which can output the real data of particle size in each channel and automatically determine the sample grade ;

    Online particle counter LPC-M3 6 The standard model can directly withstand a pressure of 100 kg, and an optional pressure reducing valve can be used for 400 kg high-pressure measurement ;

    Online particle counter LPC-M3 7 It has volume flushing and time flushing modes, which is convenient for users to use and maintain the equipment ;

    Online particle counter LPC-M3 8 Built-in IS04406, NAS1638, SAE4059, GJB420A, GJB420B, ГOCT17216 , GB/T14039 particle contamination level standards ;

    Online particle counter LPC-M3 9 Built-in calibration function, can be calibrated according to GB/T21540, IS4402, IS011171, GB/T18854 and other standards ;

    Online particle counter LPC-M3 10 Can realize multiple functions through data collection and secondary programming ;

    Online particle counter LPC-M3 11 RS485 interface, supports standard modbus protocol and can be connected to computers, PLC systems or other devices for data monitoring and processing ;

    Online particle counter LPC-M3 12 Solid appearance structure, suitable for complex working environment ;

    Online particle counter LPC-M3 13 The oil inlet and outlet are distributed on the left and right sides, which is convenient for installation ;

    Online particle counter LPC-M3 14 The test can be performed continuously or the test time interval can be set arbitrarily ;

    Online particle counter LPC-M3 15 Optional external display, with Chinese and English dual systems (optional) ;

    Online particle counter LPC-M3 16 Optional 4G module to support remote data monitoring, historical data, and curve query via mobile phone or computer (optional) .

    图片10 (4)

    Product Paramenters

    Light source 

     semiconductor laser

    Measuring range 

     1 μm ~1000 μm

    Measurement standards 

     GJB420B, SAE4059F-CPC , IS04406, GB/T14039, GJB420A, NAS1638 , SAE4059F, GOST17216

    Flow rate range 

     5mL/min ~ 500mL/min (optimal 30mL/min)

    Sample viscosity 

     ≤ 650cSt

    Sensitivity 

     1 μm or 4 μm (c)

    Counting volume 

     1~999mL

    Counting accuracy 

     ±0.5 pollution level

    Coincidence error limit

     40,000 particles/ml

    Online detection pressure

     0.1~10Mpa (optional pressure reducing device, the maximum pressure can reach 40MPa)

    Data output

     RS485 interface

    Power supply 

     DC 9-36V ; ≤ 5W

    Ambient temperature 

     -20~60 ℃

    Weight 

     < 500g

    Dimensions 

     77.5×70×55mm

    Light source 

     semiconductor laser

    Measuring range 

     1 μm ~1000 μm

    Measurement standards 

     GJB420B, SAE4059F-CPC , IS04406, GB/T14039, GJB420A, NAS1638 , SAE4059F, GOST17216

    Flow rate range 

     5mL/min ~ 500mL/min (optimal 30mL/min)

    Sample viscosity 

     ≤ 650cSt

    Sensitivity 

     1 μm or 4 μm (c)

    Counting volume 

     1~999mL

    Counting accuracy 

     ±0.5 pollution level

    Coincidence error limit

     40,000 particles/ml

    Online detection pressure

     0.1~10Mpa (optional pressure reducing device, the maximum pressure can reach 40MPa)

    Contact us
    Get in touch with us
    Just leave your email or phone number in the contact form so we can send you a free quote for our wide range of designs!
    Related Products
    no data
    +86 15699785629
    Operating hours
    Monday - Saturday(GMT+8): 8am - 8pm

    Zetron delivers innovative solutions that boost efficiency and drive growth for your business success.

    Contact with us
    Contact person: Lisa Niu
    WhatsApp:+86 15699785629
    Add:

    Office 19B, 17th Floor, Building 1, 48 Dongzhimenwai Avenue, Dongcheng District, Beijing

    Copyright © 2026 Zetron - www.bjzetron.com | Sitemap  | Privacy Policy
    Contact us
    wechat
    phone
    email
    whatsapp
    Contact customer service
    Contact us
    wechat
    phone
    email
    whatsapp
    cancel
    Customer service
    detect