Zetron FSC-A6 Air Biological Sampler

FSC-A6 six-stage sieve impact air microbial sampler is composed of an impactor, a main machine, and a microorganism sampler. The impactor is an aluminium alloy disc with 6 layers of tiny holes. The impactor is a 6-layer aluminium alloy disc with tiny holes. The discs are placed under the agar The discs are placed under the agar dish, and there is a sealing ring between each disc, and the discs are firmly connected together by three spring hooks. The discs are held together by three spring-loaded hooks. Each disc has 400 small, precisely sized holes arranged in a circular pattern, decreasing in size from layer to layer. Each disc has 400 small, precisely sized holes arranged in a circular pattern of diminishing layers, with a standard sampling flow rate of 1 cubic foot per minute. As the air stream containing microbiological particles When the airflow containing microbial particles enters the sampling port in the top layer, the microbial particles of different sizes will be impacted by the aerodynamic characteristics of the microbial particles of different sizes impact on the corresponding agar surfaces according to aerodynamic characteristics. Capture The size range of particles on each level is determined by the airflow velocity at the eyelet of that level and the particle interception rate of the previous level. cut-off rate of the previous level. Levels 1 and 2 resemble particles captured in the upper respiratory tract of humans, and levels 3-6 resemble particles captured in the lower respiratory tract of humans. levels resemble particles captured in the lower respiratory tract of humans, which replicates to a considerable degree the penetration and deposition sites in the respiratory tract.

Details

FSC-A6 Air Biological Sampler

FSC-A6 six-stage sieve impact air microbial sampler is composed of an impactor, a main machine, and a microorganism sampler.  The impactor is an aluminium alloy disc with 6 layers of tiny holes. The impactor is a 6-layer aluminium alloy disc with tiny holes. The discs are placed under the agar The discs are placed under the agar dish, and there is a sealing ring between each disc, and the discs are firmly connected together by three spring hooks. The discs are held together by three spring-loaded hooks. Each disc has 400 small, precisely sized holes arranged in a circular pattern, decreasing in size from layer to layer. Each disc has 400 small, precisely sized holes arranged in a circular pattern of diminishing layers, with a standard sampling flow rate of 1 cubic foot per minute. As the air stream containing microbiological particles When the airflow containing microbial particles enters the sampling port in the top layer, the microbial particles of different sizes will be impacted by the aerodynamic characteristics of the microbial particles of different sizes impact on the corresponding agar surfaces according to aerodynamic characteristics. Capture The size range of particles on each level is determined by the airflow velocity at the eyelet of that level and the particle interception rate of the previous level. cut-off rate of the previous level. Levels 1 and 2 resemble particles captured in the upper respiratory tract of humans, and levels 3-6 resemble particles captured in the lower respiratory tract of humans. levels resemble particles captured in the lower respiratory tract of humans, which replicates to a considerable degree the penetration and deposition sites in the respiratory tract.

Host: A set

Impactor: a stage 6 impactor

Operation manual: one copy

Connecting pipe and other special accessories: one set

Aluminum alloy suitcase: one



Parameter

measuring range

Capture rate: 98%

Capture the particle range

Level 1:> 7.0 μ m pore size 1.18mm

Level 2:4.7 μ m 7.0 μ m aperture 0.91mm

Level 3:3.3 μ m 4.7 μ m aperture 0.71mm

Level 4:2.1 μ m 3.3 μ m aperture 0.53mm

Level 5:1.1 μ m 2.1 μ m aperture 0.34mm

Level 6:0.65 μ m 1.1 μ m aperture 0.25mm

sampling quantity

28.3L/min Error is <5%

sampling period

1-99 minutes can be set arbitrarily

noise

≤50 db

working power supply

220V/AC

power

≤ 45W

Volume (WLH)

Host: 210250130 (mm) Weight: 4.7 Kg

Impactor: 110110850 (mm) Weight: 1.1 Kg

Application

l Particle analysis in a clean room and associated controlled environments

l Indoor and outdoor air quality studies

Studies on bioaerosols