TA-2.6 CARBONANALYZER TOTAL ORGANIC 1
TA-2.6 CARBONANALYZER TOTAL ORGANIC 1

TA-2.6 CARBONANALYZER TOTAL ORGANIC

  • 0.001 mg/L detection limit
  • 6 min analysis
  • TOC+conductivity
5.0
design customization

    oops...!

    no product data.

    Go to homepage
    图片2 (23)

    Compact • Portable • Reagent-Free

    Precision for High-Purity Water

    TA-2.6 oxidizes organic compounds by UV/TiO₂, measures carbon dioxide through conductivity, and calculates TOC from independently measured TC and TIC.

    TA-2.6 CARBONANALYZER TOTAL ORGANIC 3
    0.001 mg/L
    Detection limit
    TA-2.6 CARBONANALYZER TOTAL ORGANIC 4
    0.001–1.600
    Measurement range (mg/L)
    图片8 (9)
    6 min
    Analysis time
    图片7 (13)
    Designed for deionized water below 1.600 mg/L TOC

    UV Oxidation + Dual Conductivity

    The sample is split into two equal-flow paths.

    TIC is measured before oxidation; TC is measured after UV/TiO₂ oxidation.

    ScreenShot_2026-08-25_171302_767

    Built for Routine TOC Control

    TA-2.6 CARBONANALYZER TOTAL ORGANIC 8
    01
    Reagent-Free
    No acid, oxidant or carrier gas is required.
    TA-2.6 CARBONANALYZER TOTAL ORGANIC 9
    02
    Dual-Channel Detection
    Independent TIC and TC conductivity channels with temperature compensation.
    ScreenShot_2026-08-25_171302_767
    03
    TOC + Conductivity
    Reports sample conductivity together with TOC results.
    图片8 (9)
    04
    Compact & Portable
    Lightweight, energy-efficient design for flexible placement.
    图片7 (13)
    05
    High-Limit Alarm
    Configurable upper-limit alarm supports fast exception response.
    图片6 (15)
    06
    System Suitability
    Supports USP <643>, EP <2.2.44> and the 2020 Chinese Pharmacopoeia TOC method.

    Traceable Data, Direct Operation

    One touchscreen. Four core tasks.

    图片3 (22)
    TA-2.6 CARBONANALYZER TOTAL ORGANIC 15
    3
    Access Levels
    Administrator • Operator • User
    TA-2.6 CARBONANALYZER TOTAL ORGANIC 16
    12 mo
    Continuous Data
    Search, print and review stored records
    ScreenShot_2026-08-25_171302_767
    USB
    Export
    Audit trail and history records
    图片8 (9)
    PDF
    Reports
    Export or print completed results

    Audit trail records operations, timestamps, users, calibration and maintenance history.

    Designed for Critical Water Systems

    ScreenShot_2026-08-25_172049_996
    ScreenShot_2026-08-25_172059_428

    From Sample to Traceable Record

    The instrument runs the measurement sequence automatically after sample information is entered.

    TA-2.6 CARBONANALYZER TOTAL ORGANIC 21
    01
    Connect sample
    Prepare at least 300 mL and connect inlet / outlet tubing.
    TA-2.6 CARBONANALYZER TOTAL ORGANIC 22
    02
    Enter information
    Product name, product code and sampling point.
    ScreenShot_2026-08-25_172059_428
    03
    Start analysis
    The automated sequence requires no manual control.
    ScreenShot_2026-08-25_172049_996
    04
    Monitor results
    Review real-time TOC and conductivity.
    ScreenShot_2026-08-25_171302_767
    05
    Save automatically
    Completed results are stored in History.
    图片8 (9)
    06
    Print or export
    Print directly or export stored records as PDF.

    Flush the lines before testing when the instrument has been idle or after a high-TOC sample.

    Technical Specifications

    All values below are taken directly from the TA-2.6 user manual.

    ParameterSpecification
    Power supply220 V ± 22 V AC
    Power frequency50 Hz ± 1 Hz
    Rated power100 W
    Detection limit0.001 mg/L
    Measurement accuracy±4%
    Measurement range0.001–1.600 mg/L
    Analysis time6 min
    Response time≤15 min
    Sample temperature1–70 °C
    Ambient temperature10–40 °C; daily change within ±5 °C
    Relative humidity≤85% RH
    Repeatability error≤3%

    Installation & Routine Maintenance

    Installation conditions

    ParameterRequirement
    Supply voltage220 V ± 22 V AC
    Power frequency50 Hz ± 1 Hz
    Ambient temperature10–40 °C
    Relative humidity≤85% RH
    Sample temperature1–70 °C
    Ventilation clearance≥16 cm behind and on both sides

    Recommended consumable replacement

    Part No.ComponentInterval*
    19058ZUV lamp6 months
    10062ZPeristaltic pump tubing12 months

    Sample handling

    Use a filter of 60 µm or finer when visible insoluble particles are present.

    Keep the instrument on a clean, level and stable surface.

    图片2 (23)

    TA-2.6TOTAL ORGANIC CARBONANALYZER

    CONTROL ORGANIC

    CARBON WITH CONFIDENCE

    TA-2.6 combines reagent-free UV oxidation, dual conductivity detection and traceable data management in one compact analyzer.

    Contact us
    Get in touch with us
    Just leave your email or phone number in the contact form so we can send you a free quote for our wide range of designs!
    Related Products
    +86 15699785629
    Operating hours
    Monday - Saturday(GMT+8): 8am - 8pm

    Zetron delivers innovative solutions that boost efficiency and drive growth for your business success.

    Contact with us
    Contact person: Lisa Niu
    WhatsApp:+86 15699785629
    Add:

    Office 19B, 17th Floor, Building 1, 48 Dongzhimenwai Avenue, Dongcheng District, Beijing

    Copyright © 2026 Zetron - www.bjzetron.com | Sitemap  | Privacy Policy
    Contact us
    wechat
    phone
    email
    whatsapp
    Contact customer service
    Contact us
    wechat
    phone
    email
    whatsapp
    cancel
    Customer service
    detect