Zetron Instrument focuses on providing customized solutions for precision analysis and monitoring.
Product Description
The MS400-DP Natural Dew Point Meter employs the chilled mirror principle and serves as a portable, intelligent humidity measurement device. Its design integrates cutting-edge technologies—including signal detection, fuzzy control, and data processing—and utilizes high-performance imported core components to ensure the high accuracy and reliability of measurement results.
Features
Intelligent Operation: Supports the storage, retrieval, printing, and automatic uploading of measurement records.
Precise and Rapid: Features a built-in Condensation Accelerator (QCA) to ensure rapid and stable dew point detection, even under low-humidity conditions.
Dynamic Display: Provides dynamic condensation indication, displaying the real-time condensation status of the mirror surface.
Automatic Adjustment: Automatically adjusts light intensity in response to insufficient or excessive light energy; supports automatic mirror surface inspection.
Multi-Gas Measurement: Suitable for trace moisture analysis across a wide range of gases.
High-Performance Cooling: Boasts a maximum cooling differential of >95°C, ensuring measurement stability even under extreme conditions.
Portable Power: Equipped with a built-in high-capacity lithium battery, providing over 8 hours of continuous operation.
User Experience: Supports multi-language settings and features a user-friendly, optimized interface.
Functional parameters
| Function options | Technical parameters |
| Measurement range | Measured at -65℃ ~ +20℃; 10℃ ambient temperature -65℃ ~ +20℃; 20℃ ambient temperature -65℃ ~ +20℃; 35℃ ambient temperature -55℃ ~ +20℃; 40℃ ambient temperature The above are the measured values of SF6 gas at atmospheric pressure. If it is greater than atmospheric pressure The dew point temperature will be higher. |
| Measurement parameters | Dew point temperature μL/L value Equilibrium process curve Gas flow rate Ambient temperature Ambient humidity |
| Control Interface | Manual control Serial port control Remote wireless control |
| Accuracy | ≤±0.2℃ |
| Recurrence rate | ≤±0.1℃ |
| Equilibrium time | Generally 3-5 minutes (depending on the measurement environment) (Related to the degree of gas dryness) |
| Cool down | Level 4 Peltier cooling pump |
| Sampling gas flow rate | 15~60 L/H Generally 25-30 L/H |
| relative pressure of sampling gas | Minimum 10mbar Maximum 10 bar ( 1kPa~ 1MPa) |
| Display | 320×240 true color TFT high brightness LCD display |
| Alarm | Gas flow abnormality alarm Mirror inspection alarm |
| Response time | 2.5℃/second maximum |
| Instrument inspection | Automatic mirror inspection |
| Charging power input | 100-240 VAC 50Hz/60Hz |
| Host input voltage | 20V DC 6.0A |
| Maximum charging power | Maximum charging power: 120W (at maximum cooling capacity) |
| Ambient temperature | Measurement range -40℃ ~ 123.8℃ , ±0.3℃ |
| Operating temperature: 0℃ ~ 50℃ | |
| Ambient humidity | Measurement range 0%~ 100% ±2.0% |
| Measurement range | Measurement range: 0%–90% No condensation |
| Weight | Approximately 4kg |
| Size | 320mm×330mm×150 mm |
Application
Office 19B, 17th Floor, Building 1, 48 Dongzhimenwai Avenue, Dongcheng District, Beijing